The basic structure with GA / GB clamps that slide manually in the T-slot.
This system is able to control the upper die circuit, lower die circuit, and die lifter circuit individually by using 3-circuit type BC non-leak valve unit.
Auto-slide GD / GE clamps enable to slide clamps and lock the die with button operation. The proximity switch
detects that the die is locked securely, and the backward-end switch detects that the clamps are retracted.
In case malfunction occurs in the air cylinder, even the proximity switch detects the die is in place,
the press machine does not start working by interlock function unless the clamps conduct lock action.
Most suitable when it is difficult to slide clamp manually, or for reduction of manual systems.