| Molding machine input |
Content |
| Mold open OK |
A signal to indicate the clamp system is ready for mold opening. |
| Mold close OK |
A signal to indicate the clamp system is ready for mold closing. |
| Mold change "ON" |
A signal to indicate the clamp system is in "Mold Change" mode. |
| Clamp alarm |
The clamp system has an alarm condition and the machine should be stopped. |
| Hydraulic pressure demand |
A signal requesting the machine to supply hydraulic pressure to Lock or Release the clamps. |
|
|
| Note) |
| 1. |
Signals shall be sent and received at the dry contact. |
| 2. |
Use output contact for micro signal for the molding machine. (DC 24 V and 10 mA) |
| 3. |
Rating of output contact of the operation control panel is DC 24 V and 0.5 A. |
| 4. |
Be careful that each name may differ depending on the molding machine manufacturer. |
| 5. |
If you need input and output other than the above (special), contact us. |
|