| (1) |
Always install a set of air filter and regulator in the pneumatic circuit of the pump primary side. Otherwise malfunction may be caused due to contaminants in the air supply. |
| (2) |
Always use a suction filter at the pump suction side. The filter of 100-mesh or more manufactured by us or another company is recommended. |
| (3) |
Use a pipe having no rust or scale internally as a suction pipe. Remove burrs from thread part sufficiently. When installing apply a seal material such as seal tape to prevent air from entering. |
| (4) |
The pump is not suitable for continuous operation (circulation or open circuit). Always use in a closed circuit. Continuous operation results in packing wear, adversely affecting the pump life. |
| (5) |
When installing a purchased hydraulic
valve in the hydraulic circuit, the pump may not balance
to stop due to internal leakage of the valve. Continuous
operation reduces the pump life.
Use a non-leak valve manufactured by our company as
a control valve. |
| (6) |
The pump discharges oil in pulses. An accumulator can be installed to reduce pulsations. |