KOSMEK
Home          News         Contact          Sitemap         Login Japanese Chinese
Product InformationCompany InformationEmployment InformationDownloads
Home >products > KDCS > GB-Y CLAMP Catalog
KOSMEK DIECAST CLAMPING SYSTEMS
KDCS
From the actual record and know-how in plastic injection molding machine and thermal forging press, our products will endure and cope with the severe environment that usually becomes the main reason of malfunction because of the mold releasing agent or high temperature during the forming of I.M.M.

KOSMEK Diecast Clamp Systems GB-Y CLAMP CT UNIT/YMB OPERATION CONTROL PANEL
GB-Y CLAMP
The GB-Y clamp is the hydraulic clamp to clamp the mold using T slots in the die platen.
The clamp is designed for use under severe conditions where mold releasing agent and / or spattering molten metal may occur.łB
♦MODEL COAD
♦SPECIFICATION
*1: The clamping force denotes the force opposite to the mold release force.
*2: Use water, glycol or silicone oil.
Note): Determine the hydraulic oil viscosity while taking any reduction due to the molding temperature into consideration.
♦OUTLINE DIMENSIONS
♦OUTLINE DIMENSIONS
1. If you want to change the clamp stroke rate, please let us know the details.
2. determined by the T slot dimension.
3. Specify T slot dimension a, b, c and d and clamp thickness h for order.
4. Specify the dimensions of d and h to the first decimal place.
5. If dimension h exceeds the maximum h, the model becomes special specification.
6. Please contact us for specifications or dimensions not described here.
♦FEATURES OF GB-Y TYPE CLAMP
♦DESCRIPTION OF OPTION
•SPECIAL LEVER APPLICATION RANGE

Remark
1. The lever is specific, order-made.
2. Contact us for the type other than above.
♦MINIMUM DIMENSION TABLE OF MOLD CLAMP
•GB CLAMP : ALLOWABLE OVERHANG
< Precautions for mounting and operation >
1. Use the GB clamp at the normal hydraulic pressure of 24.5 MPa.
2. The T slot and the clamp area must have smooth surfaces.
If the clamp surface has protrusions or is not parallel, the force is not distributed evenly, which will cause deformation and/or oil leaks from the cylinder.
3. The clamp cannot be used when the body of the clamp overhangs through the left "L" limitation as seen through the T-slot: may damage the clamp.
•FOR FURTHUR INFORNATION ON UNLISTED SPECIFICATIONS AND SIZES, PLEASE CALL US.